CONSTRUCTION-----------------------------------------------------------------------------------------------------------------------------------------Packaged vertical Water Tube 2/3 pass Boiler.
BURNER---------------------------------------------------------------------------------------------------------------------------------------------------Complete packaged burner for on/off operation.
INSULATION AND FINISHING----------------------------------------------------------------------------------------------------------------------- The boiler shall be insulated with 50mm thick rockwool and claded with painted powder coated metallic sheet.
SAFETY-----------------------------------------------------------------------------------------------------------------------------------------------------Against over pressure, low water level, no air flow to burner and power failure.
PRESSURE CONTROLS--------------------------------------------------------------------------------------------------------------------------------For controls of burner with set pressure limit. ..
BOILER FEED WATER PUMP-------------------------------------------------------------------------------------------------------------------------Suitable for working at high pressure.
CONTROL PANEL----------------------------------------------------------------------------------------------------------------------------------------Mounted on the boiler casing, comprising of all foreign components.
EFFICIENCY------------------------------------------------------------------------------------------------------------------------------------------------Thermal efficiency 89% and fuel to steam efficiency 85% based on net calorific value of the fuel.
AFTER SALES SERVICE -------------------------------------------------------------------------------------------------------------------------------All our steam boilers are backed by our nation wide team of service technicians. Service include commissioning, maintenance contracts, breakdown calls, boiler/burner servicing and routine maintenance. Spare of all make/ brand are available through our customer service department.
DESIGN---------------------------------------------------------------------------------------As per Bangladesh Boiler Regulations. .................................
BOILER BODY-------------------------------------------------------------------------------Imported Boiler Grade Steel and Tube. .............................
OPERATION----------------------------------------------------------------------------------Fully automatic control.
WATER LEVEL CONTROLS-------------------------------------------------------------High/Low level control for feed water pump operation and extra low level for burner cut off.
| MODEL | MEL 60WT |
MEL 100WT |
MEL 150WT |
MEL 250WT |
||
|---|---|---|---|---|---|---|
Boiler Capacity F&A 100`C |
Kg/hr
|
60 |
100 |
150 |
250 |
|
Maximum Working Pressure |
Psi
|
50 |
100 |
100 |
100 |
|
Design Pessure |
Psi
|
75 |
100 |
100 |
100 |
|
Heating Surface |
Sq.m
|
1.43 |
3.15 |
5.09 |
8.65 |
|
Fuel Consumption (Natural Gas) |
SCMH
|
4.2 |
7.05 |
10.06 |
17.6 |
|
Fuel Consumption (Light Oil (HSD)) |
LPH
|
- |
7.4 |
11 |
18 |
|
Volpf Water at NWL |
Lit
|
17 |
57 |
84 |
164 |
|
Boiler Weight Dry |
Kg
|
250 |
480 |
650 |
850 |
|
Boiler Weight NWL |
Kg
|
267 |
537 |
741 |
1014 |
|
Safety Valve |
mm
|
20 |
25 |
25 |
25 |
|
Main Steam Valve |
mm
|
20 |
25 |
25 |
25 |
|
Blow down Valve |
mm
|
1.25 |
25 |
25 |
25 |
|
Chimney outlet |
mm
|
100 |
150 |
150 |
150 |
|
Power(Burner) |
Kw
|
0.37 |
0.75 |
0.75 |
0.75/0.25 |
|
Power(Feed Water Pump) |
Kw
|
0.75 |
1.1 |
1.1 |
1.5 |
|
Dimension (A) |
mm
|
452 |
615 |
700 |
900 |
|
Dimension (B) |
mm
|
1320 |
1460 |
1484 |
1517 |
|
Dimension (C) |
mm
|
1680 |
2222 |
2246 |
1864 |
|
Dimension (D) |
mm
|
1010 |
1200 |
1200 |
1300 |
|
Dimension (E) |
mm
|
750 |
815 |
900 |
1017 |
|






Other Steam Boilers |
|
![]() |
TUBELESS STEAM BOILER |
![]() |
ELECTRIC STEAM GENERATOR
|